{"product_id":"h2-filling-station","title":"H2-Refuel | High-Pressure H2 Refueling Station (350 BAR) | Automated Refueling Station  | HE-Z003R11| DILO","description":"\u003cblockquote\u003e\n\u003ch2 data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10\"\u003eAt In-Gas, our mission is simple: Don’t be a Gashole—The Quality of the Fill is the Quality of the Ride!\u003c\/b\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003c\/blockquote\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3\"\u003e\u003cbr\u003eH2-Z003R11 | H2 Refueling Station\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4\"\u003eThe Core of Your H2 Infrastructure. Automated. Cascaded. Compliant.\u003c\/b\u003e The H2-Refuel Station (H2-Z003R11) is a high-performance, automated solution designed for the safe and simple refueling of Hydrogen vehicles. By managing the supply from up to \u003cb data-index-in-node=\"244\" data-path-to-node=\"4\"\u003efour separate H2 storage tanks (cylinder bundles)\u003c\/b\u003e, this station handles the complexities of gas transfer with \"one-touch\" simplicity.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe filling process is engineered for speed and ease of use; once connected, the automated system takes over, utilizing a \u003cb data-index-in-node=\"122\" data-path-to-node=\"5\"\u003ecascaded strategy\u003c\/b\u003e to maximize the gas volume delivered to the vehicle. Depending on the pre-pressure available in your storage tanks, this unit can refuel a vehicle up to a maximum of \u003cb data-index-in-node=\"306\" data-path-to-node=\"5\"\u003e300 bar (4,350 PSI).\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6\"\u003eThe Technical:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003eCascaded Efficiency:\u003c\/b\u003e Automatically sequences through \u003cb data-index-in-node=\"53\" data-path-to-node=\"7,0,0\"\u003e4x separate H2 storage tanks\u003c\/b\u003e to optimize refueling speed and storage tank depletion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eSimplified Operation:\u003c\/b\u003e A \"quick-start\" automated process controlled via an intuitive \u003cb data-index-in-node=\"84\" data-path-to-node=\"7,1,0\"\u003eSiemens Touchscreen\u003c\/b\u003e interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eRefueling Capability:\u003c\/b\u003e Delivers up to \u003cb data-index-in-node=\"37\" data-path-to-node=\"7,3,0\"\u003e300 bar (4,350 PSI)\u003c\/b\u003e refueling pressure (dependent on supply pressure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,4,0\"\u003eLaboratory Grade Purity:\u003c\/b\u003e Designed for \u003cb data-index-in-node=\"38\" data-path-to-node=\"7,4,0\"\u003eH2 5.0 (99.999% purity)\u003c\/b\u003e to ensure long-term fuel cell health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,5,0\"\u003eRefueling Interface:\u003c\/b\u003e Standard \u003cb data-index-in-node=\"30\" data-path-to-node=\"7,5,0\"\u003eTK16-H35\u003c\/b\u003e vehicle coupling with a high-pressure hose (standard 3m length; custom lengths available).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,6,0\"\u003eGlobal Compliance:\u003c\/b\u003e Fully compliant with \u003cb data-index-in-node=\"40\" data-path-to-node=\"7,6,0\"\u003eSAE J2601-4, ISO 19880-1, and ISO 14687\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eTechnical Data:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eMax System Pressure:\u003c\/b\u003e 350 bar (5,076 PSI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eMax Refuel Pressure:\u003c\/b\u003e 300 bar (4,350 PSI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eProtection Class:\u003c\/b\u003e \u003cb data-index-in-node=\"18\" data-path-to-node=\"9,2,0\"\u003eIP65\u003c\/b\u003e (Dust-tight and protected against water jets).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eOperating Voltage:\u003c\/b\u003e 230V AC (10A Max).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eWeight:\u003c\/b\u003e 550 lbs (250 kg) empty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":52740770169200,"sku":"H2-Z003R11","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/3223\/9472\/files\/h2-z003r11-wasserstofftankstelle.959935df.png?v=1764685931","url":"https:\/\/shop.in-gas.com\/products\/h2-filling-station","provider":"In-Gas Solutions ","version":"1.0","type":"link"}